  "id": "DF-GEN-01-TP-03",
  "slug": "mismatch-hold-and-handover",
  "title": "Mismatch hold, recovery and handover",
  "objective": "Recognise a wrong profile, hold before fitting, and carry the reasoning into reviewed recovery.",
  "steps": [
    {
      "number": 1,
      "title": "Read the assigned configuration",
      "instruction": "State DF-GEN-01 / DEMO-01 and the training draft revision.",
      "component_id": "HOUSING",
      "inspection_pose": 20,
      "expected": "The exercise is tied to a configuration and source."
    },
    {
      "number": 2,
      "title": "Compare the proposed profile",
      "instruction": "Inspect B against the reference for the assigned training A.",
      "component_id": "ELEMENT_B",
      "inspection_pose": 100,
      "expected": "A visible profile difference is identified."
    },
    {
      "number": 3,
      "title": "Call HOLD",
      "instruction": "Do not force or animate B into the housing. Stop the represented task.",
      "component_id": "ELEMENT_B",
      "inspection_pose": 100,
      "expected": "B stays outside; progression is held."
    },
    {
      "number": 4,
      "title": "Capture the discrepancy",
      "instruction": "Describe the conflicting profile and the source needed to resolve it.",
      "component_id": "ELEMENT_B",
      "inspection_pose": 100,
      "expected": "The record explains the reason, not only the stop."
    },
    {
      "number": 5,
      "title": "Bring in the reviewer",
      "instruction": "A responsible instructor checks the correct source/configuration and the proposed recovery.",
      "component_id": "HOUSING",
      "inspection_pose": 62,
      "expected": "No automatic source or package approval is implied."
    },
    {
      "number": 6,
      "title": "Select verified training A",
      "instruction": "Only after instructor review, identify the assigned A in the concept exercise.",
      "component_id": "ELEMENT_A",
      "inspection_pose": 100,
      "expected": "A remains the same object; B is still separate."
    },
    {
      "number": 7,
      "title": "Inspect recovery",
      "instruction": "Review the same-axis return in the model. An actual physical task needs its own approved operating procedure.",
      "component_id": "ELEMENT_A",
      "inspection_pose": 0,
      "expected": "No lateral insertion or hidden-lock certification is inferred."
    },
    {
      "number": 8,
      "title": "Hand over the reasoning",
      "instruction": "Record the configuration, mismatch, reviewer decision, evidence and unresolved items for the next exercise.",
      "component_id": "HOUSING",
      "inspection_pose": 0,
      "expected": "An accountable review precedes any lesson or procedure update."
    }
  ],
  "version": "DRAFT-1",
  "equipment_id": "DF-GEN-01",
  "configuration": "DEMO-01",
  "status": "CONCEPT TRAINING PROCEDURE DRAFT",
  "operationally_approved": false,
  "boundary": "Inert model/approved training fixture only. Not an OEM operating SOP, service release or competence certificate."
}